| MIL-T-48621A (AR)
QUALITY ASSURANCE PROVISIONS
4.
Responsibility for inspection. Unless otherwise specified
4.1
in the contract or purchase order, the contractor is responsible for
the performance of all inspection requirements (examinations and
-
tests) as specified herein. Except as otherwise specified in the
contract or purchase order, the contractor may use his own or any
other facilities suitable for the performance of the inspection
requirements specified herein, unless disapproved by the Governman t.
The Gove rnment reserves the right to perform any of the inspections
sat forth in the specification where such inspections are deemed
necessary to assure supplies and services conform to prescribed
requirmenents.
4 . 1 . 1 ResP onsibility for compliance. All items shall meet all
requirements of Sections 3 and 5. The inspections set forth in this
specification shall become a part of the contractor's overall
Inspection system or quality
program. The absence of any inspection
requirements in the specification shall not relieve the contractor
of the responsibility of assuring that all products or suplies
submitted to the Government for acceptance comp
ly with all
requirements of the contract. Sampling in qua lity conformance does
not authorize submission of known defective material, either
Indicated or actual, nor does It commit the Government to acceptanc~
of defective material.
4.1.2 General Provisions. The component and subassembly
inspection requirements of MIL-F-13926 form a part of the quality
assurance provisions of this specification. Reference shallbe made
to MIL-STD-109 to define quality assurance terms used herein.
4.2 Classification of Inspections
The Inspection requirements
q
Specified herein are Classified as follows :
First article inspection (see.4.3).
a.
b.
Quality conformance inspection (see 4.4).
c.
Special sampling inspection (see 4.5).
4.2.1 O I l c o n d i t i o n s . Unless otherwise specified, all
examinations and
conducted at the following standard
ambient conditions:
a.
Temperature
+60 deg to +90 deg F
b.
Relative humidity
90% RH max.
c.
Pressure
28 to 32 inches of Hg
16
|