| MIL-T-48621A [AR)
n. Measure p-p signal and make the following computations for
Band 1, Band 2 and Band 3:
P-P signal x 1.259 = Reference Attenuation (MAX)
P-P Signal x 0.794 = Reference Attenuation (MIN)
Band 1 60 mV x 1.259 = 76 Reference Attenuation (MAX)
60 mV x 0.794 = 48 Referemce Attenuation (MXN)
I
Band 2 40 MV x 1.259 = SO Reference Attention (MAX)
40 mV x 0.794 = 32 Reference Attenuation (MIN)
Band 3 45 MV x 1.259 = 57 Reference Attenuation (MAX)
45 mv x 0.794 = 36 Reference AttenuatiOn (MIN)
Record the
as per the
results of the above caputations,
o.
followlng example, on the Reference Attenuation cards
attached to the cable retaining cover:
Band 1 48 to 76 mV
Band 2 32 to 50 mV
..
Band 3 36 to 57 mV
4.8 Solderinq. Soldering processes shall be Inspected by
certified inspectors to the requirements and acceptance criteria of
-
-
MIL-STD-2000 to be specified in paragraph 3.8.
5.
PACKAGING
5.1 General.
Preservation, packing and marking shall be in
accordance~pecial Packaging Instruction PS11822700. The level
of protection shall be as specified in the procurement document.
6.
NOTES
section contains Infoation of a general or
(This
explanatory natura that may be helpful, but is not mandatory.)
6.1 Intended use.
The noise tester is designed to determine
the integrated noise power of the Solid State X-Band Source
(10548182/10556651 ) over the range of 600 Hz to 2 MKz, and grade it
on a pass/fall, go/no go basis. The X-Band Source is a subassembly
of the Receiver-Transmitter, RT-860/VPS-2 (a part of Radar Set
AN/VPS-2) a subassembly of MX-8046A/TPM-22 (a part of Radar Test Set
AN/TPM-22) and a subassembly of the R.F. Control Assembly of the
Radar System Tester AN/VPM-Z.
53
|