| MIL-T-52843C
APPENDIX
TEST METHOD NO. 3
TRAVEL SPEED
1.
TEST COURSE:
The test course shall be a dry, level surface of sufficient
length to attain maximum speed prior to entering measured
distance, plus measured distance, plus sufficient stopping
distance.
2.
TEST APPARATUS:
a. Linear measurement equipment.
b. Stopwatch or electronic timer.
3.
TEST PROCEDURE:
a. Drive the forklift to attain maximum speed prior to entering
the measured test course (do not exceed an operating speed at
which the loaded forklift cannot be controlled). While
accelerating, perform gear or range changes under full
throttle. Forks shall be in the carry position, (full carriage
tilt backward).
b. Drive through the measured distance at maximum speed, recording
the length of the distance and the time required to traverse
it. The measured distance shall be not less than 88 feet.
c. Turn the forklift around and repeat the test approaching the
measured distance from the opposite end. Repeat for a total of
six runs, three in each direction through the measured
distance.
d. Conduct procedure 3a through 3c for the following:
(1) Forward with rated load.
(2) Rearward with rated load.
(3) Forward without load.
70
|