4.6.7.2.3 Resolution 12 power. - Perform this test as specified
in 4.6.7.1.10. Resolution of the 12X system shall conform to the require-
ments of 3.6.2.3.
4.6.8 Diopter knob disengagement. - Testing equipment conforming to
the requirements of 4.5.2.3.3 shall be utilized for this test. The force
(pull) required to disengage the diopter knob from its lock position shall
be within the values specified in 3.7.1 for the temperatures indicated.
4.6.9 Diopter knob rotation. - Testing equipment conforming to the
requirements of 4.5.2.3.4 shall be utilized for this test. The running
torque required to rotate the diopter knob throughout its range of
movement, in its unlocked position, shall be within the ValueS specified
in 3.7.2 for the temperatures indicated.
4.6.10 Filter transfer lever. - When the telescope is thermally
stabilized at -65 and +150F the filter transfer lever shall be subjected
to a tactile inspection. The filter transfer lever shall conform to the
requirements of 3.7.3 at each extreme temperature.
4.6.11 Articulation, torque. - Testing equipment conforming to the
requirements of 4.5.2.3.4 shall be utilized for this test. The adapter
shall be used with the torque measuring equipment to accommodate the
objective tube assembly at the articulated joint. Position the telescope
as specified in 3.7.4. Torque shall be measured while rotating the
objective tube through its full movement about the articulated joint
with the eyepiece housing assembly immobilized. The maximum running
torque required to rotate the objective tube shall not exceed the value
specified in 3.7.4 for the temperature indicated.
4.6.12 Boresight knob disengagement. - Testing equipment conforming
to the requirements of 4.5.2.3.3 shall be utilized for this test. The
force required to disengage each boresight knob from its lock position
shall be within the values specified in 3.7.5 for the temperatures indicated
4.6.13 Boresight knob rotation. - Test equipment conforming to the
requirements of 4.5.2.3.4 shall be utilized for this test. The running
torque required to rotate each boresight knob throughout its range of
movement, in its unlocked position, shall be within the values specified
in 3.7.6 for the temperature indicated.
4.6.14 Power selector lever. - When the telescope is thermally
stabilized at -65 and +150F, the power selector lever shall be subject-
ed to a tactile inspection. The power selector lever shall conform to
the requirements of 3.7.7 at each extreme temperature.
4.6.15 Lamp housing assemblies. - The lamp housing assemblies shall
be subjected to a tactile examination. The missile and conventional reticle
lamp housing assemblies shall conform to the requirements of 3.7.8 at the
temperatures indicated.