| MIL-T-62223B(AT)
TABLE II. Major defects AQL - 25 defects per 100 units. - Continued
Defect
Method of
number
Characteristic
Major defects
inspection
Visual and
108
Electrical system
Code violations, e.g. sloppy or loose
functional
connections, improper wiring
clearances, color code errors,
incorrect capacity of circuit breaker
box(es), wiring not fastened or
clipped, incorrect wire size, faulty
materials, faulty solder joints, sloppy
installation, inoperative electrical
controls, noisy (see 3.5.6 and 3.7.9)
109
Floodlights,
Not weatherproof, improper
Visual and
installation
grounding, sloppy installation,
operational
brackets not secure, brackets not
located as specified, inoperative
(see 3.5.6.7)
110
Air conditioner,
Not shockmounted, not mounted
Visual and
heater and controls
securely, improper wiring and
operational
grounding, air duct diffusers not
operative, noise, vibration, heater
and air conditioner controls not
operative (see 3.5.7, 3.5.8 and
3.7.10)
111
Plumbing system,
Water leaks, undue noise, fixtures
Visual and
components and
and components not mounted
functional
fixtures
securely. Improper assembly or
installation, defective material,
malfunction, or inoperative
(see 3.5.9 and 3.7.11)
Visual and
112
Desks, cabinets and
Delamination, scratches, mars. color
functional
counters, laminated
fade, unevenness, bulging, rough
surfaces
edges, not level with floor, not
alined or fitted, loose mounting,
poor construction, improper counter
height, interference of desks and
cabinet drawers, inoperative key
locking (see 3.5.10 through 3.5.10.4
and 3.7.12)
33
|