| ![]() MIL-T-62531(AT)
TABLE VI. Classification of defects.
Method of
Category
Characteristic
Defect
inspection
Critical
None
Major
AQL 25 Defects per 100 units
101
Engine
Malfunction, leaks (see 6.4)
Functional and
unusual noise
visual
102
Cooling system and components
Malfunction, leaks, improper
Functional and
clearance
visual
103
Governor linkage
Malfunction, seals
Functional and
visual
104
Electrical system
Malfunction, damaged,
Functional and
lighting connectors, bulbs
visual
105
Service and Hand brake and locks
Malfunction, leaks,
Functional and
adjustment
visual
106
Instrumentation switches, warning
Malfunction
Functional and
indicators
visual
107
Exhaust system
Damaged, leaks
Functional and
visual
108
Tires
Damaged, wrong-size/type
Visual and
gage
109
Winch and wire rope
Malfunction, improper size,
Functional
length, damage,
110
Speeds - high, low
Nonconformance
Functional
111
Frame structure and welding defects
Visual
112
Tank structure and welding defects
Visual
113
Controls
Malfunction, improper
Functional and
clearance
visual
114
Rustproofing
Inadequate application,
Visual
coverage.
115
Special purpose kits
Missing, improperly installed.
Visual
116
Transmission and power take off
Inoperative, malfunction,
Functional and
visual
(PTO)
leaks, improper installation of
major components, damage,
overheating, unusual noise
Minor
AQL 150 Defects per 100 units
201
Controls
Improper adjustment or
Functional and
assembly.
visual
202
Coolant
Low or improper mixture.
26
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |