| ![]() MIL-T-62531(AT)
APPENDIX C
STEPS
GUIDELINES
CLASSIFICATION
- YES
Unscheduled maintenance
9
Could malfunction have been corrected
within 60 minutes by operator/crew using
authorized OEM tools, spare parts, etc.?
NO
- YES
Unscheduled maintenance
10
Was incident an actual malfunction for
which maintenance could have been
deferred to the next scheduled unit
maintenance and corrected at that level or
deferred to end of test?
NO
11
Could tactical mission of 75 miles be
- YES
Unscheduled maintenance and
completed without any degradation to the
system failure
mission essential functions?
NO
12
Was the incident an incipient malfunction
- YES
Unscheduled maintenance and
detected during scheduled maintenance
system failure
which required direct support or higher
level corrective action?
NO
13
Did the incident concern a warn out
- YES
Unscheduled maintenance and
component that would give ample
system failure
warning prior to failure?
NO
14
Classify as system failure, and
unscheduled maintenance.
99
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |