| MIL-T-63359(AR)
4.5.2.2 Contractor design. - The contractor shall design
and supply inspection equipment compatible with the "Test
Methods and Procedures" specified in 4.6 of this specification
and with the component inspection procedures specified in
"Examination" and "Test Facilities" requirements of MIL-F-13926.
Since tolerance of test equipment is normally considered to
within 10% of the product tolerance for which it is intended,
this inherent error in the test equipment design must be
considered as part of the prescribed product tolerance limit.
Thus, concept, construction, materials, dimensions and
tolerance used in the design of test equipment shall be so
selected and controlled as to insure that the test equipment
will reliably indicate acceptability of a product which does
not exceed 90% of the prescribed tolerance limit, and permit
positive rejection when non-conforming. Construciton shall be
such as to facilitate routine calibration of test equipment.
4.5.3 Test equipment. - In conjunction with 4.5.2.2 the
following standard test equipment shall be utilized in the
performance of the applicable tests as specified in 4.6 and 4.7.
DESCRIPTION
NOMENCLATURE
Standard type conforming to
1. Hot and Cold Chamber
the accuracies outlined in
test facilities specified
under test facilities of
MIL-F-13926.
Standard shop type conforming
2.
Insulation
Resistance
to the accuracies outlined in
Checker
4.5.2.2
0 to 100 VDC output within
3.
Power
Supply
10% accuracy
Standard shop type accurate
4. Torque Wrench, Scales
to within 10% of specification
and Adapters
requirements
Standard shop type accurate
5.
Pressure
Gage
to within 10% of specification
requirement
9
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |