| MIL-T-63359(AR)
retested in accordance with 4.7.2.10. All retested telescopes
shall be aside for a minimum of 12 hours and then retested for
internal pressure in accordance with 3.5. Should the telescope
fail second test, the telescope shall be rejected.
4.7.2.10 Torque. - Torque to be measured using appropriate
adapters and torque measuring devices (scales, weights or
wrench). Torque measurements to be considered as running torque
and are to be performed under temperature conditions outlined in
3.9 and shall conform to the requirements' of 3.9.1, 3.9.2 and
3.9.3.
4.7.2.11 Insulation resistance. - This test shall be
conducted in accordance with Method 302 of MIL-STD-202, using
test condition "A". Insulation resistance measurements shall
be made between insulated points and ground. Insulation
resistance shall not be less than the value specified in 3.10.
5. PREPARATION FOR DELIVERY
5.1 Packaging, packing and marking. - Packaging, packing
and marking shall be in accordance with MIL-P-14232 and the
applicable packaging data sheet as follows:
10512082
Telescope,
Elbow:
M118A2
The level of protection shall be as specified in the procurement
document.
6.
NOTES
6.1 Intended use. - Elbow Telescope M118A2 is intended for
use as components of the primary direct fire control systems on
self-propelled howitzers.
6.2 Ordering data. - Procurement documents should specify
the following:
a. Title, number, and date of this specification.
b. Selection of applicable levels of preservation,
packaging, and packing.
c. Applicable stock numbers.
d. Applicable packaging data sheet number (see 5.1).
e.
Selection of applicable level of preservation, packaging
and packing.
13
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |