4.4.10.1 Temperature. A high temperature test shall be
performed in accordance with MIL-STD-810, Method 501.1, Prodedure I,
and a low temperature test shall be performed in accordance with
MIL-STD-810, Method 502.1, Procedure I. The minimum temperature
during the low temperature test shall be -65F and the maximum
temperature during the high temperature test shall be +160F.
4.4.10.2 Altitude. A low pressure altitude test shall be
performed in accordance with MIL-STD-810, Method 500.1, Prodedure I.
4.4.10.3 Temperature/Altitude combination. A temperature/
altitude test shall be performed in accordance with MIL-STD-810,
Method 504.1, Procedure I and equipment category 5.
4.4.10.4 Humidity. A humidity test shall be performed in
accordance with MIL-STD-810, Method 507.1, Procedure I.
4.4.10.5 Vibration. A vibration test shall be performed in
accordance with MIL-STD-810, Method 514.2, Procedure I equipment
category C, except use 0.3 inch double amplitude form 5 to 40 cps or
+3 g acceleration whichever is less and use 0.036 inch double
amplitude from 40 cps to 73 cps and +10 g from 73 cps to 500 cps.
4.4.10.6 Shock. A shock test shall be performed in accordance
with MIL-STD-810, Method 516.2, Procedure I.
4.4.10.7 Sand and dust. A dust test shall be performed in
accordance with MIL-STD-810, Method 510.1, Procedure I.
4.4.10.8 Fungus. A fungus test shall be performed in
accordance with MIL-STD-810, Method 508.1, Procedure I.
4.4.10.9 Salt fog. Samples shall be selected from each lot and
subjected to the salt spray (fog) test in accordance with the
procedure specified in ASTM Bl17. Unless otherwise specified on the
applicable drawing the minimum exposure time shall be one and
onehalf (1-1/2) hours using a 5% sodium chloride solution.
Rejection shall be in accordance with the applicable protective
finish specification.
4.4.11 Dimensions. Verify by measurement that the dimensions
of the motor meet the requirements specified on drawing 905D490.
4.4.12 Weight. Verify by weighing the motor to determine that
the motor weight is 6.8 lbs.
4.4.13 Color. Verify by observation that the color of the
motor enclosure is black wringle.