| ![]() MIL-T-63536(AR)
Input
Voltage
Output Phase Relationships
+5% in phase with Vx input, 10
V X= 10 Vrms at
a.
2.15 Vac
Pin J1-U
mVDC offset, at Pin J1-a; with VZ
input at 0 Vac
Vx Return at
Return at Pin J1-b
Pin J1-e
b. Vz= 8V rms at
5% out of phase with Vz input,
4.25 Vac
Pin J1-j
10 mVdc offset, at Pin J1-a; with
VX input at 0 Vac.
Vz Return at Pin
Vz Return at Pin J1-b
J1-f
+5% in phase with Vy input,
4.64 Vac
co Vy = 10V rms at
+10 mVdc offset, at Pins JlyX and
Pin J1-g
J1-Y
Vy Return at Pin
Return at J1-Z (for J1-Y) J1-X
return to chassis ground
J1-h
d. 28Vdc, J2-h
28 Vdc at
Note: Weapon select switch, S1, at
J2-R
20 mm position
3.6.1.3 Torque command component assembly. With input power as specified
in 3.1.3 and with the additional inputs described in 3.6.1.3.1, the following
outputs shall occur as defined in 3.6.1 .3.2 and 3.6.1.3.3.
3.6.1.3.1 Stabilized Control Augmentation System (SCAS) command signal.
When a fire volts pulse train (applied at J2-Z) and an interlocked trigger
signal are present (relay A2kl energized), a 28(+2) Vdc signal shall be on
J2-X and test connector pin J3-T.
3.6.1.3.2 SCAS output time delays. When the fire volts pulse (a square
wave test pulse train of 0 to 28 Vdc amplitude, pulse width of 40 ms, and
pulse period of 80 ms) is applied (at J2-Z) and then, the interlocked trigger
signal is applied (relay A2kl is energized by grounding Pin J2-r), the output
at Pin J2-X shall rise to 28 (2) Vdc after a delay of 50 (30) ms. When the
interlocked trigger signal is removed (Pin J2-r disconnected from ground, the
12
|