3.2 Design and Construction - Unless otherwise specified herein or in
the detail equipment specification, Contractor-Furnished Equipment (CFE)
shall conform with all the requirements of MIL-H- 15362 or MIL-T-21200 as
applicable for design, construction, and workmanship.  Government -
Furnished Equipment (GFE) shall conform to the applicable detail equipment
The total weight of the AWG-10 Side Bench Missile Control
specification.
System Test Set shall not exceed 5, 000 pounds.
3.2.1 Operational Stability - Unless otherwise specified in the individual
equipment specification, the equipment shall operate with satisfactory per -
formance, continuously or intermittently, for a period of 24 hours without
necessity for readjustment of any operator controls which are inaccessible
to the operator during use.
However, adjustments at points inaccessible to
the operator during use may be made following replacement of parts.
3. 2.2 Operating Life - The equipment shall have minimum total operating
life of 2,000 hours with reasonable servicing and replacement of parts,
3. 2.3 Cables and Connectors - The equipment shall provide for the use
of cables and connectors in accordance with MIL-H-15362 and MIL-T-21200,
as applicable.
3. 2.4 Interchangeability - Unless otherwise specified herein or in the
detail equipment specification, the equipment shall meet the interchangeabil-
ity requirements as defined in MIL-T-21200.
3. 2.5 Maintenance provisions and Field Testing - Provisions for maint-
enance shall be as specified in MIL-T-21200. Specific test points and test
facilities shall be provided to the greatest extent practicable for ease of
The color of front panel indicator lights shall
field testing and maintenance.
be in accordance with MIL-STD-803.
3. 2.6 Calibration - Test and Measuring equipment shall be calibrated at
periodic intervals established on the basis of stability, purpose, and degree
of usage. Calibration intervals shall be adjusted as required to assure
continued accuracy as evidenced by previous calibration results.