| MIL-T-81782C(AS)
TABLE III
WRAs MAINTAINED AT THE CTS
3.4.1 Maintenance capabilities. The CTS shall be capable of loading
program data into the non-destructive read-out (NDRO) of the memory
unit and into the bulk store of the power supply - storer memory. The
CTS shall provide and control the stimuli and power forms, and provide
loads required to perform functional and diagnostic testing of the WRAs
listed in Table III.
3.4.2 Test capabilities. Unless otherwise specified herein, functional
and diagnostic testing of WRAs shall be performed automatically. The
programmable counter/timer and the digital radiometer voltmeter (DRVM)
shall be operated under program control (normal) or manual control (optional).
The oscilloscope shall be operated only in the manual mode.
3.4.2.1 Computer, Digital CP-1159( )/AWG-9 tests. Operation of the
digital computer shall be verified by performance of the following tests.
3.4.2.1.1 Computer self-test. The computer self-test shall verify the
performance of the instruction repertoire and shall include:
a.
Arithmetic tests
b.
Register tests
c.
Destructive readout (DRO) memory tests
d.
Internal interrupt tests
3.4.2.1.2 Interface tests. The controls and data paths provided for the
interfaces listed shall be verified:
a.
Data processor interface controlled channel and the program
controlled channel.
b.
CTS interface
-9-
|