MIL-T-82571A(OS)
*
4.4.5.23.5 Electrical firing test.  Each electrical firing test shall be
made with only one 400 millisecond application of test potential.  The test
potential for these tests shall be 115 plus or minus 0.5 volts ac.
4.4.5.23.6 Manual firing.  During the manual firing tests, measure the
force required to actuate the solenoid valve with the push scale. The
force required shall be 25 pounds maximum.
SCHEDULE II - EXIT VELOCITY TESTS
NOTE:  A Torpedo Mk 44 Mod 1, weighing 433 plus
or minus 7 pounds, is to be fired three conse-
cutive times as outlined below.
NOTE:  A torpedo Mk 46 Mod 1, weighing 508 plus
or minus 8 pounds, is to be fired three conse-
cutive times as outlined below.
4.4.5.23.7 Observation for damage.  At the completion of velocity tests,
there shall be no damage to the torpedo or torpedo tube assembly.