MIL-T-85395(AS)
The test set shall be capable of
External power source.
3.3.2.1 .1.2
compliance with the MIL-T-28800 operational temperature
unrestricted
for class 2 equipment when powered from the external power source
requirements
3.3.4 in lieu of battery pack PN 178AS200.
specified in
The test set shall meet the test requirements of
3.3.2.1.2  Drip-proof.
MIL-STD-109 for drip proof test except the equipment shall be inclined only 15
The equipment shall operate during and after exposure.
degrees.
3.3.2.1.3  Humidity.  The test set shall meet the test requirements of
MIL-STD-81O,  Method 507.1, Procedure I,  including Method 507.1 paragraph
entitled Summary, except the maximum temperature shall be 50C.
The test set shall meet the test requirements of
3.3.2.1.4 Salt spray.
MIL-STD-81O, Method 5 09.1, Procedure 1,  including Method 509.1 paragraph
entitled Summary.
The test set shall meet the test require-
3.3.2.1.5 Explosive atmosphere.
ments of MIL-STD-81O  Method 5 11.1, Procedure I, including Method 511.1
paragraph entitled, Summary, except the maximum temperature shall be 55C and
the maximum altitude shall be 10,000 feet (3,003 meters).
The test set shall meet the test requirements of
3.3.2.1.6  Vibration.
MIL-STD-28800  for Class 2 equipment.
3.3.2.1.7  Shock.  The test set shall meet the test requirements of
MIL-STD-810, Method 516.1, Procedure I,  including Method 516.1 paragraph
entitled Summary.  The equipment shall not be operating during the test.
3.3.3 Warm-up time.  The electronics assembly shall perform its required
functions within the time periods specified in 3.3.3.1 through 3.3.3.4.
The frequency shall be swept across the Foc 2.25
3.3.3.1 Frequency sweep.
MHz band within 30 seconds after S1 or S2 is depressed.
All requirements of
the swept frequency specified in 3.5. 1.2.1 shall be met.
3.3.3.2 Detection of RF signal.
Lamp, DS-1, shall provide an indication
within five seconds after appropriate signal is applied and S1 is depressed.
3.3.3.3 Sweep and detector circuit self test. DS-1 shall indicate sweep
circuit and detector circuit (excluding detector diode) are functioning within
30 seconds after S2 is depressed.
3.3.3.4 Battery self test.
DS-2 shall indicate battery condition within five
seconds after S1  or S2 is depressed.
3.3.4 Primary input power requirements.
The power required shall be one of
the following types and shall be not greater than the specified amounts:
A fully charged battery pack which meets the requirements of drawing
a.
178AS200.