MIL-T-85472A(AS)
3.4.2.1.5 Fungus.  The test set shall be resistant to fungi in both the
operating and nonoperating condition and shall not be adversely affected
when tested in accordance with 4.9.5.
3.4.3 Warm-up time.  The time required for the equipment to warm-up prior
to operation shall be not greater than 10 minutes under standard conditions
and 30 minutes under service conditions.
3.4.4 Primary input power requirements.  The test set shall meet input
power requirements as specified in MIL-STD-704 for Class 2 equipment.  The
power required shall be of the following type and shall be not greater than
the specified values:
a.
115
volts ac, 60
Hz, 1 phase, 3400 volt-amperes
b. 30 (+2.0) (-0.0) volts dc, 5 amperes
3.4.4.1 Electrical overload protection.  Electrical overload protection for
the test set group shall conform to Requirement 8 of MIL-STD-454 for Class 1
equipment.
3.4.5 Electromagnetic interference.  The generation of electromagnetic
interference by the test set and the susceptibility of the test set to
electromagnetic interference shall be in accordance with MIL-STD-461 as
referenced in MIL-E-16400.
3.4.5,1 Conducted susceptibility, power leads.  The test set group shall
not be susceptible to signals from 50 Hz to 400 MHz injected on the 115 V ac
power leads as specified in MIL-STD-461, Requirement CS02.
3.4.5.2 Conducted emission, power leads.  Conducted emissions from the test
set group power leads shall be within the limits of MIL-STD-461,
Requirements CE02 and CE04.
3.4.5.3 Conducted emission, control, and signal leads. Conducted emissions
from the test set control and signal leads shall be within the limits of
MIL-STD-46l, Requirements CE03 and CS05.
3.4.5.4 Radiated susceptibility.  The test set shall not be susceptible to
radiated signals from 30 Hz to 12.4 GHz as specified in MIL-STD-461,
Requirements RS01, RS03 and RS03.1.
3.4.5.5 Radiated emission, electric field. Radiated emissions from the
test set over the frequency range of 14 Hz to 1000 MHz, shall be within the
limits of MIL-STD-461, Requirement RE02.
3.4.5.6 Transient voltage.  The test set group shall meet the requirements
of MIL-E-16400 for transient high and low voltage.
3.4.5.7 Transient frequency.  The test set group shall meet the
requirements of MIL-E-16400 for transient high and low frequency.
3.4.5.8 Power interruption.  The test set group shall meet the requirements
of MIL-E-16400 for power interruption.
3.4.6 Dimensions.  The dimensions of the test set group shall be not
greater than the following: