| ![]() MIL-V-3083D
4.4.3 Test. Each vibrator shall be tested as specified in 4.5.2.6. Failure of the test shall be cause for
rejection.
4.5 Inspection procedure.
4.5.1 Examination. The vibrator shall be examined for the following defects:
Major
101.
Materials not as specified (see 3.3).
102.
Material not resistant to corrosion and deterioration, or treated to be resistant to
corrosion and deterioration for the applicable storage and operating environments
(see 3.3.1).
103.
Dissimilar metals, as defined in MIL-STD-889, are not effectively insulated from
each other (see 3.3.1.1).
104.
Contractor does not have documentation available for identification of material,
material finisher or treatment (gee 3.3.1.2).
105.
Used, rebuilt or remanufactured components, pieces or parts incorporated in the
remolding set (see 3.3.2).
106.
Dimensions and weight not as specified (see 3.4.1).
107.
Vibrating head not as specified (see 3.4.1).
108.
Eccentric weight or airmator not as specified (see 3.4.2).
109.
Throttle riot as specified (see 3.4.3).
110.
Hose handle and airhose not as specified (see 3.4.4 and 3.4.4.1).
111.
Oiler and air strainer not as specified (see 3.4.5).
112.
Lubricants not as specified (see 33.5).
113.
Human factors engineering not as specified (see 3.7).
114.
Safety not as specified (see 3.12).
Minor
201.
Identification marking not as specified (see 3.9).
202.
Treatment and painting not as specified (see 3.10).
203.
Workmanship not as specified (see 3.11).
4.5.2 Tests.
4.5.2.1 Test conditions. The vibrator shall operate as specified herein, without maintenance, other
than the contractor' recommended normal scheduled maintenance as established by a maintenance schedule
s
prepared and submitted by the contractor prior to the test. During the test, the vibrator shall be lubricated
with the oils and greases specified in 3.5. Oils shall be those designated for use in the ambient at the place
of the test. Human factor considerations (see 3.7) shall be evaluated throughout testing.
a. During the tests failure of the vibrator the design or performance requirements specified herein,
shall be caused for rejection.
b. Spillage or leakage of any fluid, including fuel, coolant, lubrication or hydraulic fluid, under
any operation condition except as allowed herein.
4.5.2.2 Frequency of vibration and air consumption. Air used for this test shall have a line pressure of
90 psi. Install a flow meter in the airline between the air supply and the vibrating head and operate the