Click here to make tpub.com your Home Page

Page Title: Sampling for examination
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-V-46727C(AT)
4.5 Quality conformance inspection.
4.5.1 Sampling.
4.5.1.1 Lot formation. An inspection lot shall consist of all the valves of one type and part
number, from an identifiable production period, from one manufacturer, submitted at one time
for acceptance.
4.5.1.2 Sampling for examination. Samples for quality conformance examination shall be
selected in accordance with general inspection level II of MIL-STD-105. Before sampling may
be initiated, the contractor shall establish by examination of at least 20 consecutively produced
assemblies that the process average percent defective, as defined in MIL-STD-105, is not greater
than the specified AQLs.
4.5.1.3 Sampling for test. Samples for tests shall be selected in accordance with level S-3 of
MIL-STD-105.
4.5.2 Examination.
4.5.2.1 Acceptable quality level. Each sample selected in accordance with 4.5.1.2 shall be
examined to determine conformance to the following acceptable quality levels (AQL).
Classification
AQL
Major
1.0
Minor
2.5
4.5.2.2 Classification of defects. For examination purposes, defects shall be classified as
listed in table II.
TABLE II. Classification of defects.
Method of
Category
Defect
examination
None
Critical
AQL 1.0% Defective
Major
SIE 1/ or
101
Dimensions affecting interchangeability not within
functional
tolerance (see 3.3).
SIE
102
Threads not as specified (see 3.3.3).
Visual
103
Valve spool stem wipers or seal missing or
defective (see 3.3.4).
SIE
104
Valve spool hardness not as specified (see 3.3.4).
SIE
105
Valve spool surface finish in excess of that
specified (3.3.4).
Functional
106
Hydraulic balance of spool not within limits
(see 3.3.4).
Functional
107
Binding (see 3.3.4).
9

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business