| MIL-V-82443(OS)
TABLE VI
VIBRATION SCHEDULE
Acceleration, ready condition. in the ready condi-
4.4.4.5
tion, shall be subjected to the accelerations defined in Table VII after
being secured to an acceleration equipment (see Figure 1). Acceleration
shall be measured at the approximate geometric center of the valve.
TABLE VII
ACCELERATION SCHEDULE
4.4.4.6
Shock, ready condition. The valve, in the ready condition,
shall be attached to a shock test machine (see Figure 1). Shock magni-
tudes and durations shall be measured by an accelerometer mounted on the
mounting fixture. Tests on the valve shall be performed in accordance
with Table VIII in the sequence shown.