| MIL-V-82444A(OS)
TABLE VI
VIBRATIONS SCHEDULE
4.4.4.5 Acceleration, ready condition. The valve, in the ready cond-
ition, shall be subjected to the accelerations defined in Table VII
after being secured to an acceleration equipment (see Figure 1).
Acceleration shall be measured at the approximate geometric center of
the valve.
TABLE VII
ACCELERATION SCHEDULE
4.4.4.6 Shock, ready condition. The valve, in the ready condition,
shall be attached to a shock test machine (see Figure 1). Shock magni-
tudes and durations shall be measured by an accelerometer mounted on the
mounting fixture. Tests on the valve shall be performed in accordance
with Table VIII in the sequence shown.
11
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |