| ![]() MIL-V-85830(AS)
Table I.
Qualification inspection.
Sample number
Inspection
Requirement
Test method
123
Visual
4.8.1
x
x
x
Suction leakage
3.9.1.1
4.8.2. 1.1
x
x
x
Pressure leakage
3.9.1.2
4.8.2. 1.2
x
x
x
Pressure drop
3.9.2
x
x
x
4.8.2.2
Back pressure
3.9.3
4.8.2.3
x
x
x
Insulation resistance
3.9.4
4.8.2.4
x
x
x
Pressure and flow/external power/ground
3.9.5
4.8.2.5.1
x
x
x
Pressure and flow/battery power/ground
3.9.5
4.8.2.5.2
x
x
x
Pressure and flow/external power/10000 ft
3.9.5
4.8.2.5.3
x
x
x
Electromagnetic comparability
3.9.6
4.8.2.6
x
Delivery hose noise
3.9.7
4.8.2.7
x
Agent permeation/mustard
3.9.8
4.8.2.8.1
Agent permeation/Vx
3.9.8
4.8.2.8.2
Agent permeation/thickened soman
3.9.8
4.8.2.8.3
Endurance/electrical
3.9.9.1
4.8.3.1
x
Endurance/mechanical
3.9.9.2
4.8.3.2
x
High temperature
4.8.4,1
3.9. 10.1
See
Table VI
Low temperature
3.9. 10.2
4.8.4.2
See
Table VI
Salt fog
3,9. 10.3
4.8.4.3
See
Table VI
Rain
3.9. 10.4
4.8.4.4
See
Table V
Fungus
3.9. 10.5
4.8.4.5
See
Table V
Low pressure and high humidity
3.9. 10.6
4.8.4.6
See
Table VI
Dust
3.9. 10.7
4.8.4.7
See
Table VI
Normal acceleration
3.9. 10.8
4.8.4.8
See
Table VI
High temperature, diurnal cycle and high
3.9. 10.9
4.8.4.9
See
Table VI
humidity
See
Table VI
Shock
3.9.10.10
4.8.4.10
See
Table VI
Vibration
3.9.10.11
4.8.4.11
See
Table VI
Battery - Temperate
4.8.5,1
3. 10.4.3.1
x
Battery - Cold weather
3.10.4.3.2
4.8.5.2
x
22
|