| MIL-W-70467 (AR)
4. 5.5.6 Load test of lever shaft. Apply the axial load
perpendicular to the lever and in such a direction as to test the
assembly of the lever and lever shaft. The required force shall act
against the lever. Upon removal of the required force, the maximum
permissible gap shall be inspected for compliance with the drawing
requirement. Any lever shaft that fails the requirement shall be
classed defective.
4.5.5.7 Load test of lever pallet. Apply an axial load
perpendicular to the lever and in such a direction as to test the
assembly of the lever and the lever pallet. The required force
shall act against the lever. Upon removal of the required force,
the height of the lever pallet above the lever shall be inspected
for compliance with the drawing requirement. Any lever pallet that
fails the requirement shall be classed defective.
4.5.5.8 Load test of annular gear. Apply a load perpendicular
to the rotor and in such a direction as to test the assembly of the
annular gear studs to the annular gear and the rotor. The required
force shall act against the rotor. Upon removal of the required
force, the distance from the face of the rotor to the outside face
of the annular gear shall be inspected for compliance with the
drawing requirement. Any annular gear that fails the requirement
shall be classed defective.
4.5.5.9 Load test of lock roller pin. Apply an axial load
perpendicular to the rotor and in such a direction as to test the
strength of the assembly of the lock roller pin to the rotor. The
required force shall act against the rotor. Any lock roller pin
that fails the requirement shall be classed defective.
4.5.5.10 Torque test of lever shaft. A torque shall be applied
between the lever and the lever shaft. Any lever shaft that fails
the requirement shall be classed defective.
4.5.5.11 Load test of bridge rivet. Apply the required load
perpendicular to the inner plate and into the bridge rivet from the
side opposite the bridge. The required force shall act against the
inner plate. Any bridge rivet that fails the requirement shall be
classed defective.
4.5.5.12 Load test of spring stud. Apply an axial load
perpendicular to the rotor housing and in such a direction as to
test the assembly of the spring stud and the rotor housing. The
required force shall act against the rotor housing. Any spring stud
that fails the requirement shall be classed defective.