MIL-W-70467 (AR)
4.5.5.13 Load test of pillars.  Apply the required axial load
perpendicular to the inner place and in such a direction as to test
the assembly of the pillars to the inner plate and outer plate.  The
required force shall act against the inner plate.  Any pillars that
fail the requirement shall be classed defective.
4.5.5.14 Torqu e test of rotor stop stud (eccentric pin).  The
required torque shall be applied between the rotor stop stud and
gear assembly.  The required force shall act on the gear assembly.
Any rotor stop stud that fails the requirement shall be classed
defective.
4.5.5.15 Load test of detonator.  Apply a five pound minimum
axial load perpendicular to the rotor and in such a direction as to
test the strength of the staking of the detonator in the rotor.  Any
staked detonator that fails the requirement shall be classed
defective.
WARNING:
This test may be dangerous and should be performed behind
a suitable barricade.
4.5.5.16 Arming and detent functioning.  The S&A, in the safe
position, shall be assembled to the test equipment in accordance
with 4.4.4.  The equipment shall accelerate the Safety and Arming
device to 20.75 g's maximum for a minimum of three plus one, minus
zero seconds in a direction which simulates rocket launch.  At the
completion of acceleration, the equipment shall be halted and visual
observation shall be made for the locking position of the detent.
Finger tip pressure shall be applied to the rotor to rotate in the
safe direction to ascertain positive arming.  At the completion of
the test, the safety and Arming Device shall be returned to the safe
position.  Any S&A that fails the requirement shall be classed
defective.
WARNING:
This test may be dangerous and should be performed behind
a suitable barricade.
4.5.5.17 Setback weight return capability.  This test shall be
performed as specified on drawing 9215617.  S&A's failing to comply
with the specified requirements shall be classed defective and
removed from the lot.  Defect standards for verification of the
inspection process shall be in accordance with 4.4.4.3 and 4.4.4.4.
Defect standards for use with automatic equipment shall be as
follows:
a.  Units with setback weights which bind when depressed and
remain in the depressed condition.