MIL-W-70467 (AR)
b.  Units with setback weights which start to return but do not
completely return to the original locking position.
c.  Units with setback weights which return from the depressed
condition at a slower than normal rate causing rejection.
4.5.5.18 Rotor reset capability.  The loaded S&A shall be
assembled to the test fixture in accordance with 4.4.4.  The rotor
shall be rotated to a position at least 26 degrees, but not more
.
than 35 degrees, from the fully safe position and released.
Observation shall be made for rotor return to the fully safe
position.  S&A's failing to comply with the specified requirement
shall be classed defective and removed from the lot.
4.5.5.19 M423 S&A arming time test.  The loaded S&A with the
g-weight in the downward position shall be assembled to the test
equipment in accordance with 4.4.4.  The equipment shall accelerate
the Safety and Arming Device in a clockwise direction to 27.00 g's
plus or minus 0.25 g's and the arming time shall be recorded to the
nearest hundredth of a second using a calibrated timer.  S&A's
failing to comply with the specified requirements shall be classed
defective and removed from the lot.
4.5.5.20 M423 S&A non-arming test.  The loaded S&A with the
g-weight in the downward position shall be assembled to the test
equipment in accordance with 4.4.4.  The equipment shall accelerate
the Safety and Arming Device in a clockwise direction to 11.25 g's
minimum for a minimum of three (3) seconds.  Observation shall be
made for rotor in the safe position.  S&A's failing to comply with
the specified requirements shall be classed defective and removed
from the lot.
4.5.6 Radiographic.  X-ray and fluoroscopically view each round
in two planes, 90 opposed.  Verify that all major components,
assemblies, and sub-assemblies are present and properly placed, that
the S&A in the unarmed position and no foreign material is present.
Any warhead that fails the requirements shall be removed from the
lot .
4.5.7 Rough handling test.  The rough handling test shall be
performed as follows on each of thirty-six (36) warheads for first
article testing only:
45