Click here to make tpub.com your Home Page

Page Title: Type Q3 cable assemblies
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
MIL-C-17694/l(SH)
Type Q3 cable assemblies. T w o conductors of the PQ3 shall be terminated with
a pigtail consisting of:
( a ) Parts 531 and 530, as shown on Drawings S8101-1449531 and
S8101-1449532.
( b ) Nine feet, 0 inch of 2000 MCM, 61 by 19/.0415 inch tin or alloy
c o a t e d copper.
( c ) Part 528 as shown on Drawings S8101-1449531 and S8101-1449532.
The other two conductors of the PQ3 s e c t i o n shall be terminated with a pigtail
c o n s i s t i n g of:
( a ) Parts 531 and 530, as shown on Drawings S8101-1449531 and
S8101-1449532.
( b ) T e n f e e t , 0 inch of 2000 MCM, 61 by 19/.0415 inch tin or alloy
c o a t e d copper.
(c) Part 529 as shown on Drawings S8101-1449531 and S8101-1449532.
These ends of the PQ3 conductors shall be staggered 1 foot as shown on Drawing
S8101-1449530. T h e other ends of the four conductors shall be continuous with the
AQ3 cable. E a c h conductor of the other end of the AQ3 cable shall be terminated
w i t h a pigtail consisting of:
( a ) P a r t s 5 3 3 , 534, and 535m and shown on Drawing S8101-1449533.
( b ) E i g h t f e e t , 6 inches of 1000 MCM, 61 by 7/.0484 inch MHD copper
cable.
(c) Part 536 as shown on Drawing S8101-1449533.
Assembly. The two AQ conductors joined to the two shorter PQ conductors
shall form the short leg and the two AQ conductors joined to the two longer PQ
c o n d u c t o r s shall form the long leg. T h e short leg shall be connected directly to
a K4 electrode. T h e long leg shall be connected to an S cable which then connects
t o a K4 electrode. T h e short and-long legs shall be staggered 1 foot, 3 inches as
shown on the following drawings:
TABLE V.
S h o r t and long leg staggering.
QUAD CABLE SAMPLE SECTIONS:
P Q cable sections. For PQ cable sections, one
pair of components shall be
s e p a r a t e d out, c u t to a length of 5 feet, terminated
in the same reamer as the
s t r e n g t h t e s t . One component
e x i s t i n g  terminations, a n d s u b j e c t e d t o t h e t e n s i l e
o f the other pair shall be subjected to the flexing
test.