Pump wearing parts only shall be furnished when pumps are built in such that complete assembly cannot
be furnished.
tube nests are required only when tubes are welded or brazed.
3.6.1.1 The quantity of each particular item in
furnished as required by the applicable specifi-
a set of repair parts is based on the number of com-
cations.
pressors having that item, even though the compres-
sors may be of different classes (see 3.2, 4), For
3.6.3 Special tools. -
example, a set of repair parts may be intended to
service an installation of 3 class A and 2 class B,
3. 6.3.1 Maintenance tools. - Each set of special
compressors; the quantity of such parts as are used
maintenance tools required by a contract or order
on all classes shall be based on 5 compressors; any
shall consist of tools such as babbitting mandrels,
parts used on class B compressors only shall be
trams for setting piston clearances, cooler tube ex-
based on 2 compressors.
panders and test rings, and gear wheel, flywheel,
and coupling pulling tools, required for the proper
3.6.2 Repair parts for motors, controllers,
repair and maintenance of the compressors. Each
pressure switches and other devices shall be
set of special tools shall be furnished in a separate