MIL-C-64025
4.5.7.23  FSD transfer test.  Apply Transfer Load II to the
SENDER as specified in Figure lb. Enter the TRANSFER key and verify
the FSD pulse sequence with the requirements of 3.9.18.2 and that the
SENDER displays "SENDING" in compliance with the requirements of
3.9.18.1. Verify-that the FSD data conforms to the RCD code of
4.5.7.20 as specified by Drawing 9333026 for the Current group.
After the FSD pulse sequence has been sent, verify that the SENDER
displays "n TRANSFER", where n is the current GROUP ID, in compliance
with the requirements of 3.9.18.3.
4.5.7.24  Group select-ion test.  Enter the GRP ID key anti verify
that the SENDER displays "n NONE", where n is the next GROUP ID
number ,  in compliance with the requirements of 3.9.15.2$ 3.9.15.3,
3.9.17.1, and 3.9.17.3.
Repeat 4.5.7.23 and 4.5.7.24
4.5.7.25  Group addressing test.
for each of the remaining groups thru group 15. Verify compliance with
the requirements of 3.9.15.1.
Invalid FSD transfer test.
Enter the GRP ID key and
4.5.7.26
verify the display response of "ALL" as per requirements 3.9.15-3 and
3.9.17.2. Enter the TRANSFER key and verify that the SENDER displays
"ALL INVALID" in compliance with the requirements of 3.9.18.4.
Voltage regulation.  Measure the voltage at A2-E44
4.5.7.27
(+5VDC) and verify compliance with the requirements of 3.9.1.
4.5.7.28
Command transmission.
For each entry in the following
table,
Command Test Table
n
m
g
2
2
4.9%
9,
8, or 7
20
7
3
9.4%
38
4
7,
6, or 5
13.9%
56
19.0%
5
5
75
23 .5%
5,
4, or 3
6
93
111
7
26.8%
4,
3, or 2
8
129
2
34.5%
1
147
9
52.5%
10
0
165
100.0%
11
100.0%
183
0
12
202
100.0%
0
13
220
100.0%
0
14
0
100.0%
239
15
256
100.0%
0
v is a percentage +_ 100 millivolts of the regulation
Note:
voltage measured in 4.5.7.27.
do the following sequence:  Enter the GRD ID key; verify that the
display reads "g TRANSFER" where g is the current GROUP ID; enter the
DEPLOY key and verify that the display reads "DEPLOY g" in compliance
147