b. Move S25 to the right.
L71 and L72 should come on and
L68 should go off.
Push S9; L32 should go off.
c.
4.6.2.7.3.5 TEST OF LEFT TAPS/XMTR CIRCUITS.
Complete the BACP set-up. Move S14 to the right. Move
S22 to the left. Move S14 to the left. Move S14 to the right.
Move S14 to the left. Then move S24 to the left. L70 and L72
should go off and L68 and L31 should come on.
b. Move S24 to the right.
L70 and L72 should come on and
L68 should go off.
Push S9; L31 should go off.
c.
4.6.2.7.3.6 TEST OF LEFT TAB CIRCUITS.
Complete the BACP set-up. Move S15 to the right. Move
S22 to the left. Move S14 to the right. Move S14 to the left.
Move S16 to the right; L61 should come on. Move S14 to the right;
(wait 10 seconds) L61 should go off, L34 should come on. The
Malfunction lamp on the OCP should come on.
b. Move S14 and S16 to the left. Push S9.
L34 should go
off; the Malfunction lamp on the OCP should go off.
4.6.2.7.3.7 TEST OF RIGHT TAB CIRCUITS.
Complete the BACP set-up. Move S14 to the right. Move
S23 to the left. Move S15 to the right. Move S15 to the left.
Move S17 to the right. L62 should come on. Then move S15 to the
right (wait 10 seconds). L62 should go off, L35 should come on.
The Malfunction lamp on the OCP should come on.
b. Move S15 and S17 to the left. Push S9.
L35 should go
off; the Malfunction lamp on the OCP should go off.
4.6.2.7.3.8 TEST OF RIGHT MAGAZINE BYPASS CIRCUITS.
a. Complete the BACP set-up. Move S17 to the right; L62
should come on. Then move S17 to the left; L62 should go off.
4.6.2.7.3.9 TEST OF LEFT MAGAZINE BYPASS CIRCUITS.
a. Complete the BACP set-up. Move S16 to the right; L61
should come on. Then move S16 to the left; L61 should go off.