| MIL-D-63303B(AR)
e. Set the Right Magazine switch to .005. L91 should blink
with each reduction of the count on the OCP. L19 and L49 should
come on; L18 and L48 should go off.
f. Set the Right Magazine Density switch to .007. L19 and
L47 should go off; L20 should come on.
g. Set the Right Magazine Density switch to .01. L47, L48
and L21 should come on; L20 and L49 should go off.
h. Set the Right Magazine Density switch to .025. L47 and
L21 should go off; L22 should come on.
i. Set the Right Magazine Density switch to MAX. L19
should stay on constantly. L47, L23 and L80 should come on; L48 and
L22 should go off.
Replace Launcher Gate Pin.
j.
4.6.2.7.3.16 TEST OF LEFT JAMMED MINE CIRCUITS.
a. Complete the BACP set up. Hold S11 to the left. L36.
and L37 should come on. The Malfunction lamp on the OCP should come
on.
Release S11.
b.
Press "Reset" S9. L36 and L37 should go off. Hold S12
to the left; hold Sll tO the left. Release S11, then release S12.
L36 and L37 should come on. The Malfunction lamp on the OCP should
come on.
Press S9.
d.
4.6.2.7.3.17
TEST OF RIGHT JAMMED MINE CIRCUITS.
a. Complete the BACP set-up. Hold S11 to the right. L36
and L37 should come on. The Malfunction lamp on the OCP should come
on.
Release S11.
b.
c. Press "Reset" S9. L36 and L37 should go off. Hold S12
to the right; hold S11 to the right. Release S11, then release
S12. L36 and L37 should come on. The Malfunction lamp should come
on.
Press S9.
d.
48
|