| MIL-F-48067
(MU)
4.3.2.1 Fuze Assembly, After Assembly of Lead-In (see dwg. 9268198).
Defects
Method of
Code No.
Categories
Inspection
None defined.
Critical:
AQL 0.40 percent
Major:
101.
Explosive lead-in not flush to
01001
.015 above flush . . . . . . . . . . . . . . . . . . Gage
Minor:
AQL 0.65 percent
201.
Evidence of poor workmanship
(see 3.6) . . . . . . . . . . . . . . . . . . . . . . . . Visual
01002
4 . 3 . 2 . 2 Fuze Assembly, Prior to Crimp (see dwg. 9268198).
Defects
Method of
Code No.
Categories
Inspection
None defined.
Critical:
Major:
AQL 0.40 percent
101.
Pellet, pad or closing disc
missing . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Visual-
Manual
02001
Minor:
AQL 0.65 percent
201.
Evidence of poor workmanship
(see 3.6) . . . . . . . . . . . . . . . . . . . . . . . . . Visual
02002
4.3.2.3 F u z e A s s e m b l y
(see dwg. 9268198).
Categories
Defects
Method of
Code No.
Inspection
Critical:
None defined.
Major:
AQL 0.65 percent
101.
Length from shoulder to end of
b o o s t e r assembly, max. . . . . . . . . . . . . Gage
03001
102.
Varnish missing from aft end . . . . . . Visual
03002
103.
Varnish where not permitted . . . . Visual
03003
Minor:
AQL 1.50 percent
201.
Marking missing, misleading or
u n i d e n t i f i a b l e . . . . . . . . . . . . . . . . . . . . Visual
03004