| MIL-F-48235 (MU)
pulses (p ositive and negative). Observe output to determine
compliance e with 3.51b, c and d. (If the actuating mechanism
fails to return to the original cocked postion during the cold
functioni ng test, the rubber boot may be manually manipulated
to cause return of the actuating mechanism.) Place bail in
safe posi tion (in vertical slot), and depress handle. Observe
that bail prevents handle from being fully depressed and mech-
anism doe s not actuate (3.501a), The firing device shall be
functione d within three (3) minutes after removal from the temp-
erature c onditioning chamber, Bail must remain in the safe
position (in vertical slot) at completion of Functioning Test.
4.4.4 Load test of male connector. - With the connector
held securely, the required force shall be applied at the
soldering end of each prong separately in a smooth gradual man-
ner so not to exceed its loading requirement as specified in
the applicable drawings.
4.4.5 Pull test of crimped connection.-With the connector held
securely, the required force shall be applied to the crimped end of
each wire, separately, at a rate not to exceed 1/8 inch per minute.
Observation shall be made for compliance with the applicable drawing
requirement.
PREPARATION FOR DELIVERY
5.
5.1 Packaging
5.1.1 Level A. - Fifty firing devices shall be packaged
in a fiberboard box complete with half-slotted partitions as-
sembied to form two layers of 25 cells in a 5 by 5 arrangement.
A plain fiberboard pad shall be placed on the bottom of the box
and on top of each layer of cells. The box shall conform to
the requirements of PPP-B-636 for a Type CF, Class Domestic,
Variety SW, Grade 200. The partitions and pads shall be con-
structed of' the same fiberboard material as the box. Cell size
shall be approximately 3 3/8 by 1 3/8 by 4 1/4 inches in depth,
inside dimensions. Pads shall be equal to the inside length
and width of the box less 1/16 inch. Box size shall be approx-
imately 17 1/2 by 7 1/2 by 9 inches inside dimensions. Boxes
shall be closed and a length of 2 inch side gummed, kraft tape,
PPP-T-45, Type III, Grade B, shall be applied over the full
length of the top and bottom center seam of the box with approx-
imately 2 inch extension of tape onto the end panels of the box.
26
|