| MIL-F-50253A (AR)
b. The M433 fuze shall cause the warhead to detonate
high order upon impacting natural round surface in "super quick"
mode or after a given number of milliseconds as determined by the
predetermined fuze set time.
3.7 Umbilical Continuity (M433),- (Fuze Unarmed).- The
continuity of the charge circuit through its umbilical, shall be
220 ohms minimum and 3.3K ohms maximum.
3.8 Data Requirements. - The contractor shall generate data
in accordance with the requirments of the data item descriptions
cited in 4.5.5.
3.9 First Article Inspection.- This specification makes
provisions for first article inspection (see Table 1), Require-
ments for the submission of first article samples by the contractor
shall be as specified in the contract.
QUALITY ASSURANCE PROVIS IONS
4.
4,2 Classification of Inspection.- The following types of
inspection shall be conducted on this item:
a.
First Article Inspection
Quality Conformance Inspection
b.