| ![]() MIL-G-1298A
TABLE I. Malfunctions, nonacceptable conditions, and
rounds without substitution of any com-
unserviceable components (see note) - Continued
ponents, and without malfunctions, in excess
of the limits shown in table 1. The machine-
gun shall complete the first 5,000 rounds of
the test without replacement of any com-
ponents.
3.15 Barrel erosion. Barrels shall be cap-
able of firing the specified number of rounds
without excessive deterioration, and shall
meet the specified accuracy and velocity re-
quirements. (See 6.1.)
3.16 Workmanship. Finished machineguns
shall be free of defects which may affect ser-
viceability, functioning, operation, safety, or
appearance.
TABLE I. Malfunctions, nonacceptable conditions,, and
unserviceable components (see note)
Note. When malfunctions (within the allowances of
table I are are traceable to particular components, it is
permissible to replace such component and record
them as unserviceable, subject to limitations of table
I. When it is definitely established by the inspector
t h a t previously recorded malfunctions are attri-
butable to an unserviceable component, such mal-
functions shall not be counted against the machine-
gun being tested, provided that they occurred not
more than 200 rounds prior to replacement of the
unserviceable component. However, such malf unc-
tions shall remain recorded and properly identified.
4. QUALITY ASSURANCE PROVISIONS
4.1 Sampling.
|