| ![]() MIL-L-85776A(AS)
4.1.1 Responsibi]ity for compliance. All items shall meet all requirements
of sections 3 and 5. The inspection set forth in this specification shall become
a part of the contractor's overall inspection system or quality program.
The
absence of any inspection requirements in the specification shall not relieve the
contractor of the responsibility of ensuring that all products or supplies
submitted to the Government for acceptance comply with all requirements of the
contract.
Sampling inspection, as part of manufacturing operations, is an
acceptable practice to ascertain conformance to requirements, however, this does
not authorize submission of known defective material, either indicated or actual,
nor does it commit the Government to accept defective material.
4.1.2 Test requirement and inspection facilities. The manufacturer shall
ensure that test and inspection facilities of sufficient accuracy, quality, and
quantity are established and maintained to permit performance of required
inspections.
All test and measurement equipment shall be calibrated and
maintained in accordance with MIL-STD-45662. Unless otherwise specified herein,
all test and measurement equipment shall have an accuracy within one-fifth of the
tolerance for the variable to be measured.
4.1.3 Certification.
When specified, a written certification (see 6.2 and
6.3), accompanied by objective quality evidence (as defined in MIL-STD-109) that
the materials and processes conform to the requirements Indicated on the drawings
and specifications listed on DL1335AS700 and DL1335AS900, shall be available to
the acquiring activity.
4.1.4 Classification of characteristics. The characteristics verified by
the tests and examinations herein are classified as major or minor in accordance
with DOD-STD-21O1.
Requirements that are major characteristics are identified by
the symbol (M). The number following the classification symbol indicates the
serial number of the requirement. Requirements which are not annotated with a
classification code are classified as minor.
4.2 Classification of inspections.
The inspection requirements
specified herein are classified as follows: -
First article .inspection (see 4.4).
a.
b. Quality conformance inspection (see 4.5).
4.3 Inspection conditions. Unless otherwise specified herein, all
inspections shall be performed in accordance with the test conditions specified
in the "General Requirements" of MIL-STD-81O (see 6.2).
4.4 First article lnspection. First article inspection shall be performed
on sample units produced with equipment and procedures normally used in
production.
4.4.1 Sample
Unless otherwise specified, first article sample shall
consist of five launchers and five sets of unassembled metal parts (see 6.2 and
6.4).
4.4.2
Inspection routine. The first article inspection shall consist of the
inspections specified in table I.
Failure to pass any one of the inspections
shall be cause for rejection.
4
|