| ![]() MIL-M-38510/118B
Device table
Device type
01
02
03
04
-10 V
-10 V
-6.25 V
-6.25 V
VIN
40.2 Ω
14.3 Ω
10 Ω
2.5 Ω
RL
2.0 F
2.0 F
1.0 F
1.0 F
Ci, CL
NOTES:
1. ei = 1 Vrms at f = 2400 Hz (measured at the input terminals of the DUT).
Ripple rejection = 20 log (eirms / eorms).
2.
The control pin connection is required for device types 01 and 02 only.
The input 50 Ω resistor and RL shall be type RER 70 or equivalent.
3.
The meter for ei and eo shall have a minimum bandwidth from 10 Hz to 10 kHz and shall measure
4.
true rms voltages.
FIGURE 10. Ripple rejection test circuit.
27
|