| ![]() TABLE III. Group A inspection for all device types Continued.
Applied voltages
Applied digital
DUT digital
Active
Measurement
Limits
Units
ref. pin 9
code-word
output
relays
sense lines
Equations and notes
(figures 6, 8)
code-word
ref. pin 9
Subgroup Symbol Test
Min
Max
29 <-------------> 40
29 <-------------> 16
7
11
1
Pin
Value
Unit
no.
VEE
VDD
VCC
MSB <------------> LSB
MSB <------------> LSB
(V)
(V)
(V)
8
For end-point linearity error,
LE(N) = (E(N+760)+E(N+761)) / 2-V(ideal)) / S
V(ideal) = N1* S+E761-S/2
TA =
+125C
N1 = Applied ref DAC code-word
S = (E760-E761) / 4094
1111 1111 111φ
581
+15.0
-15.0
+5.0
1111 1111 1110
KA
13
E760
V
0000 0000 000φ
582
"
"
"
0000 0000 0000
"
"
E761
"
Determine the code-word and the value of the maximum positive Linearity Error for all combinations of the digital input code words from (0000 0000 0000) to
(1111 1111 1111).
<-----(N1-1)----->
<-----(N-1)----->
583
+15.0
-15.0
+5.0
0
+1.0
LSB
KA
13
E762
V
LEmp
LEmp = (E762+E763) / 2-N1*S-E761+S / 2) / S
<-----(N-1)----->
<-----(N)----->
"
"
"
"
"
E763
"
All device types
Determine the code-word and the value of the maximum negative Linearity Error for all combinations of the digital input code words from (0000 0000 0000) to
(1111 1111 1111).
<-----(N1-1)----->
<-----(N-1)----->
584
+15.0
-15.0
+5.0
-1.0
0
LSB
KA
13
E764
V
LEmn
LEmn = (E764+E765) / 2-N1*S-E761+S / 2) / S
<-----(N-1)----->
<-----(N)----->
"
"
"
"
"
E765
"
All device types
For Linearity Error, the worst positive and negative error values, as determined by the manufacturer's abbreviated Integral Linearity Error (LE) test procedure for subgroup 4 shall be within 150 milliLSB of the
worst positive and negative error values, as determined by the all codes test.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |