Page Title: Table 3. Group A inspection for device type 04-cont.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 




img
TABLE III. Group A inspection for device type 04 - Continued.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
method
terminal
11
12
13
14
15
16
17
18
Subgroup 1
Subgroup 2
Subgroup 3
TC = +25C
TC = +125C
TC = -55C
K
15
16
17
18
21
22
23
24
Test No.
D3/Q3
D2/Q2
D1/Q1
D0/Q0
A9
A8
A7
VDD
Min
Max
Min
Max
Min
Max
A
IDD1
3005
85
GND
GND
GND
5.5 V
VDD 5/
250
250
250
IDD2
86
"
"
"
"
VDD 6/
"
"
"
"
IDD3
87
"
"
"
"
VDD 7/
"
"
"
"
IDD4
88
"
"
"
"
VDD 13/
"
"
"
"
Subgroup 4
TC = +25C
Min
Max
Each
CI
3012
89
8/
8/
8/
GND
10
pF
input
Subgroup 8
TC = +125C
Min
Max
PWR
90
9/
9/
9/
9/
VDD
3.0
V
DWN 16/
Functional
10/
10/
10/
10/
Q
10/
10/
V
91
tests 16/
Subgroup 9
Subgroup 10
Subgroup 11
TC = +25C
TC = +125C
TC = -55C
Min
Max
Min
Max
Min
Max
tAVQV
Fig. 4
92
11/
11/
11/
11/
11/
11/
11/
4.5 V
Q
320
320
320
ns
tELQV
93
11/
11/
11/
11/
11/
11/
11/
4.5 V
Q
300
300
300
ns
Subgroup 12
TC = +25C
Min
Max
IDDOP
94
12/
12/
12/
12/
12/
12/
12/
5.5 V
VDD
7
mA
See footnotes at end of table III.