| TABLE III. Group A inspection for device type 05.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
1
2
3
4
5
6
7
8
9
10
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
2
3
4
5
7
8
9
11
12
13
Test No.
A0
A1
A2
A3
A4
A5
Q
VSS
Min
Max
Min
Max
Min
Max
CE
W
100 A
VIC (POS)
1
A0
0.1
3.0
V
100 A
2
A1
"
"
"
100 A
3
A2
"
"
"
100 A
4
A3
"
"
"
100 A
5
A4
"
"
"
100 A
6
A5
"
"
"
100 A
7
"
"
"
W
100 A
8
"
"
"
CE
9
D
"
"
"
10
A11
"
"
"
11
A10
"
"
"
12
A9
"
"
"
13
A8
"
"
"
14
A7
"
"
"
15
A6
-0.1
-3.0
"
-100A
VIC (NEG)
16
GND
A0
"
"
"
-100A
17
"
A1
"
"
"
-100A
18
"
A2
"
"
"
-100A
19
"
A3
"
"
"
-100A
20
"
A4
"
"
"
-100A
21
"
A5
"
"
"
-100A
"
22
"
"
"
W
-100A
23
"
"
"
"
CE
24
"
D
"
"
"
25
"
A11
"
"
"
26
"
A10
"
"
"
27
"
A9
"
"
"
28
"
A8
"
"
"
29
"
A7
"
"
"
30
"
A6
"
"
"
IOL
3007
31
GND
GND
GND
GND
GND
GND
0.4 V
4.75 V
"
GND
Q
4.0
2.5
4.0
mA
IOH
3006
32
GND
GND
GND
GND
GND
GND
4.35 V
4.75 V
"
GND
Q
-3.0
-2.0
-3.0
mA
A
IIH
3010
33
5.25 V
GND
GND
GND
GND
GND
GND
"
GND
A0
2.0
10
34
GND
5.25 V
GND
"
"
"
"
"
"
A1
"
"
"
35
"
GND
5.25 V
"
"
"
"
"
"
A2
"
"
"
36
"
"
GND
5.25 V
"
"
"
"
"
A3
"
"
"
37
"
"
"
GND
5.25 V
"
"
"
"
A4
"
"
"
38
"
"
"
"
GND
5.25 V
"
"
"
A5
"
"
"
39
"
"
"
"
"
GND
5.25 V
"
"
"
"
"
W
40
"
"
"
"
"
"
GND
"
5.25 V
"
"
"
CE
41
"
"
"
"
"
"
"
"
GND
D
"
"
"
42
"
"
"
"
"
"
"
"
"
A11
"
"
"
43
"
"
"
"
"
"
"
"
"
A10
"
"
"
44
"
"
"
"
"
"
"
"
"
A9
"
"
"
45
"
"
"
"
"
"
"
"
"
A8
"
"
"
46
"
"
"
"
"
"
"
"
"
A7
"
"
"
47
"
"
"
"
"
"
"
"
"
A6
"
"
"
See footnotes at end of table III.
|