| TABLE III. Group A inspection for device type 05 Continued.
Terminal conditions 1/
Test limits
Symbol
MIL-STD-
Case V
Measured
Unit
883
11
12
13
14
15
16
17
18
Subgroup 1
Subgroup 2
Subgroup 3
method
terminal
TC = +25C
TC = +125C
TC = -55C
K
15
16
17
18
21
22
23
24
Test No.
D
A11
A10
A9
A8
A7
A6
VDD
Min
Max
Min
Max
Min
Max
VIC (POS)
1
GND
A0
0.1
3.0
V
2
"
A1
"
"
"
3
"
A2
"
"
"
4
"
A3
"
"
"
5
"
A4
"
"
"
6
"
A5
"
"
"
7
"
"
"
"
W
8
"
"
"
"
CE
100A
9
"
D
"
"
"
100A
10
"
A11
"
"
"
100A
11
"
A10
"
"
"
100A
12
"
A9
"
"
"
100A
13
"
A8
"
"
"
100A
14
"
A7
"
"
"
100A
15
"
A6
"
"
"
VIC (NEG)
16
A0
-0.1
-3.0
"
17
A1
"
"
"
18
A2
"
"
"
19
A3
"
"
"
20
A4
"
"
"
21
A5
"
"
"
22
"
"
"
W
23
"
"
"
CE
-100A
24
D
"
"
"
-100A
25
A11
"
"
"
-100A
26
A10
"
"
"
-100A
27
A9
"
"
"
-100A
28
A8
"
"
"
-100A
29
A7
"
"
"
-100A
30
A6
"
"
"
IOL
3007
31
GND
GND
GND
GND
GND
GND
GND
4.75 V
Q
4.0
2.5
4.0
mA
IOH
3006
32
GND
GND
GND
GND
GND
GND
GND
4.75 V
Q
-3.0
-2.0
-3.0
mA
A
IIH
3010
33
"
"
"
"
"
"
"
5.25 V
A0
2.0
10
34
"
"
"
"
"
"
"
"
A1
"
"
"
35
"
"
"
"
"
"
"
"
A2
"
"
"
36
"
"
"
"
"
"
"
"
A3
"
"
"
37
"
"
"
"
"
"
"
"
A4
"
"
"
38
"
"
"
"
"
"
"
"
A5
"
"
"
39
"
"
"
"
"
"
"
"
"
"
"
W
40
"
"
"
"
"
"
"
"
"
"
"
CE
41
5.25 V
"
"
"
"
"
"
"
D
"
"
"
42
GND
5.25 V
"
"
"
"
"
"
A11
"
"
"
43
"
GND
5.25 V
"
"
"
"
"
A10
"
"
"
44
"
"
GND
5.25 V
"
"
"
"
A9
"
"
"
45
"
"
"
GND
5.25 V
"
"
"
A8
"
"
"
46
"
"
"
"
GND
5.25 V
"
"
A7
"
"
"
47
"
"
"
"
GND
GND
5.25 V
"
A6
"
"
"
See footnotes at end of table III.
|