| MIL-M-50747(MU)
8 August 1973
Pulse widths = 1.0 + 0.2s
tr and tf < 40 ns (1O and 90 percent amplitude points)
Figure 5. MALF 3 input Signal Waveforms
3.3.2 Environmental
3.3.2.1 Storage temperature. The assembly shall meet the
requirements of 3.3.1 at ambient temperature after exposure to and
thermal stabilization at -80F and +160F.
3.3.2.2 Operating temperatures. The assembly shall meet the
requirements of 3.3.1 while exposed to and thermally stabilized at -40 F
and +125F, subsequent to which the requirements of 3.3.1 shall be met
at ambient temperature.
3.3.2.3 Vibration, The assembly shall show no physical failure
and shall meet the requirements of 3.3.1 after being exposed to the
following vibratory conditions:
a. Amplitude:
1/64 inch, constant
(1/32 inch double amplitude)
b.
Vibratory motion: Simple harmonic
c.
5 to 55 to 5 Hertz in a five-
Sweep time:
minute period
Three linear or logarithmic sweeps
d. Vibration cycling:
applied to each of the three mutually
perpendicular axes.
|