| MIL-N-85005A(AS)
3.5.6.8
Electrical Connections - Connections to external circuits
shall be provided as listed.
Receptacle
Reference
Designation
Type
Function
2J1
M81511/41FH02P1
Converter-Interface
2J2
M81511/41FE01S3
AGE
System Power - The equipment shall utilize power from
3.5.6.9
the Converter (Para. 3.5.5.9) as follows:
(1) 115 VAC, 400Hz, 30, Category B, 25 VA.
(2) 5 VDC, 56 watts.
Mounting - The TDC shall be designed for installation
3.5.6.10
on the modified horizontal surface immediately below and in front of the
ITAD and IP-886B/ASA-66 units.
Color - The surface shall be painted lusterless gray,
3.5.6.11
No. 36231, in accordance with FED-STD-595.
Marker Placard - An adhesive placard shall be located
3.5.6.12
on the TDC to identify normal marker usage, and shall be labeled as follows:
39
PRIORITY FLY-TO
1 - 31 SONOBUOY
40
32 - 33 SURFACE
TARGET PREDICT
34 - 35 RADAR
41 - 60
GENERAL PURPOSE
36 - 38 MAD
- 92 -
|