MIL-P-18472G(SH)
5.
PACKAGING
(The packaging requirements specified herein apply only for direct Govern-
ment acquisition.  For the extent of applicability of the packaging requirements
of referenced documents listed in section 2, see 6.7.)
5.1 Preservation, pack ing and marking.  Pump units and accessories shall be
preserved level A or C, and packed level A, B, or C (see 6.3) as specified (see
6.2).
6.
NOTES
(This section contains information of a general or explanatory nature that
may be helpful, but is not mandatory.)
6.1
Intended use.  Pumps covered by this specification are intended for
condensate, boiler feed booster, waste heat boiler, and distilling plant services
on board Naval ships.
6.2  Acquisition requirements.
Acquisition documents must specify the
following:
(a) Title, number, and date of this specification.
(b) Issue of DoDISS to be cited in the solicitation, and if required,
the specific issue of individual documents referenced (see 2.1.1
and 2.2).
(c) When first article is required (see 3.1).
(d) Class required (see 1.2).
(e) General design required (see 3.2).
(1) Space and weight requirements (see 3.2).
(2) List, pitch, roll, trim, and other ship attitude conditions
(see 3.2, 3.2.7, and 4.6.3.3).
(3) Environmental vibration frequencies (see 4.6.3.4).
(4) Airborne, structureborne,  and fluidborne noise requirements
(see 3.2.4 and 4.6.1.4).
(5) Ambient temperature, normal, maximum, and minimum.
(f) Performance-characteristics (see 3.2 and 3.3.2).
(1)
Rated capacity and range of capacity.
(2)
Rated total head at rated capacity.
(3)
Fluid to be pumped.
(4)
Specific gravity of fluid.
Temperature of fluid, normal, maximum and minimum (see
(5)
3.3.2.1.1  and  4.6.1.3).
(6)
Suction head available, normal, maximum, and minimum and flow
control method (see 3.3.2.1.1, 4.6.1.3, 4.6.2.1 and
4.6.3.1.3).
(7)
Casing design and test pressures.
(8)
Special performance requirements, if any (for example,
maximum shutoff head).