MIL-P-70624A(AR)
3.6.11 Electronics box assembly.  When Figure 7 is applied as
shown in 4.5.4.11, the "READY" light will go OFF on the first pulse,
shall stay OFF during the second pulse and will come `ON" between 6
to 10 seconds.  The "FAIL" light shall stay OFF.
3.6.12  Ambient temperature (75F 10F).  After
conditioning as specified in 4.5.4.14, the Electronics Box Assembly
--
shall meet the requirements specified in 3.6.1 through 3.6.11.
3.6.13  Cold temperature (Minus 25F - 5F).  After
conditioning as specified in 4.5.4.15, the Electronics Box Assembly
shall meet the requirements specified in 3.6.1 through 3.6.11.
3.6.14  Hot temperature (120F + 5F).  After conditioning
as specified in 4.5.4.16, the Electronics Box Components Assembly
shall meet the requirements specified in 3.6.1 through 3.6.11.
3.6.15  Transportation vibration.  After Electronics Box
Components Assembly is subjected to vibration as specififed in
4.5.4.17, the Electronics Box Components Assembly shall meet the
requirements as specified in 3.6.1 through 3.6.11.
9

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business