Input Power Requirements:
3.3.1.6
The power required shall not exceed the specified amounts under
service conditions. The equipment shall not be damaged when
subjected to the power transient limits of MIL-STD-704.
(1)
115 v
AC Power (Single-Phase)
Operating Voltage Limits
103.5 - 126.5 volts
Operating Frequency Limits
380 - 420 cps
Power (1 0)
175 V.A.
(2)
AC Power (Three-Phase)
Operating Voltage Limits
103.5 to 126.5 volts line to
neutral
Operating Frequency Limits
380 to 420 cps
Power (3 0)
900 V.A.
DC Power -28 Volt System
(3)
Operating Voltage Limits
24.75 to 30.25 volts
4 amps.
Current
3.3.1.6.1
Undervoltage Protection:
The equipment shall not be damaged by voltages below the
minimum specified herein and shall automatically resume
normal operation when the voltage returns within limits.
Terminations:
3.3.1.7
RF Terminations:
3.3.1.7.1
The RF input to the receiver shall be through a 51.5-ohm resist-
ive only) dummy antenna and the value of 51.5 ohms shall include
the internal impedance of the signal generator. The RF output
of the transmitter shall be into a 51.5-ohm resistive load.
Audio Terminations:
3.3.1.7.2
The audio output (headset) of the receiver shall be terminated
in a 300-ohm non-inductive load which shall include means for
measuring the audio frequency power output. The audio (micro-
phone) input circuit of the transmitter shall be connected to
an audio frequency generator with a dummy microphone having
characteristics as listed below.