| MIL-R-5757/10L
REQUIREMENTS:
Contact data:
High level characteristics 1/
Low level characteristics 2/
Configuration
DPDT
DPDT
Arrangement
2 form C
2 form C
Load ratings (relay case grounded):
Resistive
See table I
10 to 50 microamperes at 10 to 50
mV, dc or peak ac
Not applicable
Inductive
See table I
Lamp
See table I
Not applicable
Intermediate current:
Applicable
Not applicable
Contact resistance or voltage drop:
Rated life:
Before
.05 ohm maximum
.05 ohm maximum
During
10 percent of open circuit voltage
50 ohms maximum
After
.10 ohm maximum
.15 ohm maximum
Intermediate current:
Before
.05 ohm maximum
Not applicable
During
3 ohms maximum
Not applicable
After
3 ohms maximum
Not applicable
Contact bounce
1 millisecond (ms) maximum
2 ms maximum
Overload test:
Resistive
2 times rated current
Not applicable
Inductive
2 times rated current
Not applicable
TABLE I. High-level load ratings.
Amperes
Type of load
28 V dc
115 V 400 Hz 1/
115 V 60 Hz
0.3
0.3
2.0
Resistive
0.3
0.3
1.0 2/
Inductive
0.1
0.1
Lamp 1/
0.1
1/ Life test not required.
2/ At an inductive load of 200 millihenries minimum.
___________
1/ High-level relays are not designed for use at low-level loads.
2/ Relays intended for low-level applications shall not be tested at high level or with lamps.