| MIL-R-5757/10L
Coil data: See table II.
Duty rating: Continuous.
Operate time (over temperature range): 6 milliseconds maximum.
Release time (over temperature range): 6 milliseconds maximum.
TABLE II. Dash numbers and applicable characteristics.
Coil voltage 1/
Over temperature range
Dash
(V dc)
Config-
Vibra-
Terminals
Pickup
Hold
Dropout
Coil resistance
at 25C
number
uration
tion
voltage
voltage
voltage
(g's)
(V dc)
(V dc)
(V dc)
(Ohms)
5/
(Max)
(Rated)
Max
Low level relays
015
F
20
32
26.5
18
14
1.5
540 min to 770 max
L
016
F
20
32
26.5
18
14
1.5
540 min to 770 max
W
022
B
20
32
26.5
18
14
1.5
540 min to 770 max
PC
064
D
20
32
26.5
18
14
1.5
495 min to 770 max
Plug-in
065
E
20
32
26.5
18
14
1.5
495 min to 770 max
Plug-in
High level relays
035
14
1.5
540 min to 770 max
G
L
20
32
26.5
18
036
14
1.5
540 min to 770 max
G
W
20
32
26.5
18
037
14
1.5
540 min to 770 max
F
L
20
32
26.5
18
038
14
1.5
540 min to 770 max
F
W
20
32
26.5
18
039
14
1.5
540 min to 770 max
A
L
20
32
26.5
18
040
14
1.5
540 min to 770 max
A
PC
20
32
26.5
18
043
14
1.5
540 min to 770 max
B
L
20
32
26.5
18
044
14
1.5
540 min to 770 max
B
PC
20
32
26.5
18
052
14
1.5
540 min to 770 max
H
L
15
32
26.5
18
053
14
1.5
540 min to 770 max
H
W
15
32
26.5
18
054
14
1.5
540 min to 770 max
H
PC
15
32
26.5
18
675 10%
056
14
1.5
J
PC
15
32
26.5
18
44 10%
059
3.0
.14
H
PC
15
7.3
6.0
4.2
060
6.0
.32
194 +10%, -15%
H
PC
15
14.7
12.0
8.9
1,000 5%
066
3/
4/
C
Plug-in
20
30
---
2/
194 10%
12.0
6.0
.32
067
A
Plug-in
20
14.7
12.0
1/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2/ Pickup current: 6.0 mA .5 mA dc.
3/ Hold current: 5.8 mA dc.
4/ Dropout current: 3.45 mA dc.
5/ Frequency range 10 to 2,000 Hz.