  | ![]() MIL-S-51368B(EA) 
5.1.3.1.8 Filter, gas, 150 CFM, M23 (D5-19-1221) and filter, particulate, 
150 CFM, M24 (C5-19-1226).  These filters shall be packaged and marked as 
specified on the packaging data sheet which is identified by the national 
stock number. 
Packing, level A (see 6.3). 
5.2 
5.2.1 M51 shelter system (less filters) (PL5-19-6523) and accessory items 
(5.1.3).  The accessory items preserved and packaged as specified herein 
shall be located on the trailer as shown on Drawing E5-19-6523.  The shelter 
system shall be prepared for shipment in accordance with Drawing D5-19-6589. 
5.2.2 M66 filter and utilities unit (less filters) (PL5-19-6821) and 
accessory items ( 5.1.3.1.1 and 5.1.3.l.2).  The accessory items preserved 
and packaged as specified herein shall be located on the trailer in ac- 
cordance with Drawing  E5-19-6821.  The filter and utilities unit shall be 
prepared for shipment in accordance with Drawing D5-19-6589. 
5.2.3 Filter, gas, (E5-19-5211-20) filter, gas, (E5-19-5211-10), filter 
particulate, ( C5-19- 5209-20), filter particulate, (C5-19-5209-1O), filter, 
gas, 150 CFM, M23 (D5-19-1221) and filter particulate, 150 CFM, M24 (C5- 
19-1226).  These filters , packaged as specified in 5.1.3.1.6, 5.1.3.1.7 
and 5.1.3.1.8 shall be packed for shipment in a skidded, wood box confom- 
ine to class 2 (overseas), style 4, type 1 (easy load), 250-4000 pound 
weight of contents of PPP-B-621.  The packaged filters shall be arranged 
in the shipping container on end.  Fiberboard filler pads conforming to 
type CF, class weather-resistant, grade W5C of PPP-F-320 shall be included 
as necessary to make a tight pack.  The box shall be closed and strapped 
in accordance with the appendix to PPP-B-621.  The strapping shall conform 
to type I, class B of QQ-S-781. 
5.3 Marking.  In addition to any special marking required by the con- 
tract or order, marking shall be as follows: 
Marking of these items shall be in ac- 
5.3.1 Unit packin g (5.1.3). 
cordance with MIL-STD-129. 
5.3.2 M51 shelter system (less filters) (5.2.1).  Marking of the shelter 
system shall be in accordance with Drawing D5-19-6589. 
5.3Q.3 Filters and utilities unit (less filters) (5.2.2). Marking of 
the filter and utilities unit shall be in accordance with Drawing D5-19-6825. 
16 
 | 
| 
 
 Privacy Statement - Press Release - Copyright Information. - Contact Us  |