| MIL-D-63303B(AR)
e. Runaway maqazine shutdown. Unload all mines.
Disconnect wiring harness connector to the right infeed conveyor TAB
sensor and attempt to launch mines from the right magazine. Return
"FIRE" switch to the "OFF" position and observe for compliance with
the applicable requirement. Reconnect TAB sensor. With the "FIRE"
switch in the "OFF" position, verify that the magazine will not
"creep" by actuating the right servo manual override in each
direction (forward and reverse), when -in the dispense and
load/unload modes.
NOTE:
1. Prior to, during and after 4.6.2.7.5, activate "BITE"
lamp test switch to insure all lights operational.
2. To clear red warning lights on "BITE" panel after
detecting "faults", push reset button on "BITE" panel.
.
3. The original sensors on the dispenser should be used for
these tests. If not possible due to extreme environmental
conditions, extra sensors may be temporarily substituted
provided they experience the same environmental conditioning
as the dispenser under test and are installed in place of
the original sensors as soon as conditions permit.
4.6.2.7.6 Liqhts. All lights shall be operated during and
after the break-in run, throughout all stages of operation, and
checked for functional requirements. Non-conformance with the
applicable requirement will constitute a failure of this test.
4.6.2.7.7 Circuit card assemblies (CCA). To determine
conformance to 3.4.2.5.9, the CCA(S) shall be inspected for
compliance with the applicable requirements.
4.6.2.8 Dispenser and systems assembly and adjustments.
4.6.2.8.1 Adjustment mechanism checks. To determine compliance
with 3.4.2.6, all adjustment mechanisms requiring adjustment shall
be checked for proper adjustment.
4.6.2.9 Chassis.
4.6.2.9.1 Brake adjustment check. To determine conformance to
3.4.2.7.1, the brakes shall be checked for trapped air and for
proper adjustments.
4.6.2.9.2 Levelinq jacks. To determine conformance to
3.4.2.7.2, the dispenser shall be fully loaded as specified (See
3.5.2.2) and shall be observed for compliance with the applicable
functional and physical requirements.
52
|