| MIL-D-63303B(AR)
c. Right magazine switch in LOAD.
Load 300 practice mines into each magazine marking one set of
300 to differentiate from the other 300. Loading shall be in
compliance with 3.5.2.2.
4.6.2.13.3 Magazine reel rates test. While loading and down
loading, check magazine reels for compliance with the requirements
of 3.5.2.3.
4.6.2.13.4 Launcher sweep rate test. During dispenser warm-up,
check launch sweep rate as follows:
a.
Mode selector switch in DISPENSE.
b.
Left magazine switch in OFF.
c.
Right magazine switch in OFF.
d.
Launcher in READY.
e.
pattern selector switch in 3.
The rate shall be observed for compliance with 3.5.2.4 and shall
be the average of ten (10) cycles (after a minimum of fifteen (15)
cycles).
4.6.2.13.5 Launcher oscillation angle, full sweep test. Test
the oscillation sweep as follows:
Mode selector switch in DISPENSE.
a.
Pattern selector switch in 3.
b.
Without dispensing practice mines, perform the oscillation sweep
test and observe for compliance with applicable requirement. Visual
observation of travel of launcher pointer with respect to the angle
markings on oscillator base is acceptable as a minimum.
4.6.2.13.6 Launcher wheel speed test.
After loading, check
wheel speed as follows:
a.
Mode selector switch in DISPENSE.
Left magazine switch in OFF.
b.
c.
Right magazine switch in OFF.
54
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |