MIL-M-38510/245B
TABLE IV. Delta limits at +25C.
Limits 2/
Parameters 1/
01, 02
03
04
05, 06
+5 A
+15 A
+25 A
+30 A
IDD
VOL
+60 mV
+60 mV
+60 mV
VOH
-200 mV
-400 mV
-400 mV
10%
IOL, IOH
500 nA
IOHZ, IOLZ
50 nA
100 nA
100 nA
IIL, IIH
1/ Conditions and mechanization of measurements shall be as specified in table III, subgroup 1.
2/ Delta limits apply to an increase from the initial value (e.g., pre-life test IIH = -120 nA, post-life test
IIH = -170 nA).
4.5.4 ESDS testing. ESDS testing in accordance with MIL-STD-883, method 3015, will be performed at initial
qualification and after any processor design changes affecting input protection circuits.
4.5.5 Quiescent supply current test. When performing quiescent supply current measurements, the meter shall
be placed so that all currents flow through the meter.
4.6 Data reporting. When specified in the contract or purchase order, a copy of the following data, as applicable,
shall be supplied:
a. Attributes data for all screening tests (see 4.2) and variables data for all static burn-in, dynamic burn-in, and
steady state life test.
b. A copy of each radiograph.
c. The quality conformance inspection data (see 4.4).
d. Parameter distribution data on parameters evaluated during burn-in.
e. Final electrical parameters data.
5. PACKAGING
5.1 Packaging requirements. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel,
these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging
requirements are maintained by the Inventory Control Point's packaging activity within the Military Service or Defense
Agency, or within the military service's system command. Packaging data retrieval is available from the managing
Military Department's or Defense Agency's automated packaging files, CD-ROM products, or by contacting the
responsible packaging activity.